parent
1175d7d58b
commit
c148b2a67a
|
|
@ -503,6 +503,14 @@ public class DeviceInfo implements Serializable {
|
||||||
@TableField("INSTALLATION_POSITION_Z")
|
@TableField("INSTALLATION_POSITION_Z")
|
||||||
private Double installationPositionZ;
|
private Double installationPositionZ;
|
||||||
|
|
||||||
|
/**
|
||||||
|
* 渗压计到孔底距离
|
||||||
|
*/
|
||||||
|
@ApiParam(value = "渗压计到孔底距离")
|
||||||
|
@ApiModelProperty(value = "渗压计到孔底距离", dataType = "java.lang.Double")
|
||||||
|
@TableField("DIST_FROM_OSMOSIS_METER_TO_BOTTOM")
|
||||||
|
private Double distFromOsmosisMeterToBottom;
|
||||||
|
|
||||||
/**
|
/**
|
||||||
* 安装纬度
|
* 安装纬度
|
||||||
*/
|
*/
|
||||||
|
|
|
||||||
|
|
@ -152,7 +152,10 @@ public class DeviceDataServiceImpl extends ServiceImpl<DeviceDataMapper, DeviceD
|
||||||
BigDecimal decimal = GR.add(KT);
|
BigDecimal decimal = GR.add(KT);
|
||||||
|
|
||||||
dd.setOsmometer(decimal);
|
dd.setOsmometer(decimal);
|
||||||
dd.setPipeZ(decimal.multiply(BigDecimal.valueOf(o_z_modulus)));
|
// dd.setPipeZ(decimal.multiply(BigDecimal.valueOf(o_z_modulus)));
|
||||||
|
//加“渗压计到孔底距离”,浮点(三位小数)同步数据时计算出的管水位加上这个数值
|
||||||
|
// 2022-10-08 lyf
|
||||||
|
dd.setPipeZ(decimal.multiply(BigDecimal.valueOf(o_z_modulus)).multiply(BigDecimal.valueOf(di.getDistFromOsmosisMeterToBottom())));
|
||||||
}
|
}
|
||||||
|
|
||||||
if (super.save(dd)) {
|
if (super.save(dd)) {
|
||||||
|
|
|
||||||
|
|
@ -21,7 +21,7 @@
|
||||||
|
|
||||||
<select id="listAll" resultType="com.whdc.zhdbaqapi.model.entity.DeviceInfo">
|
<select id="listAll" resultType="com.whdc.zhdbaqapi.model.entity.DeviceInfo">
|
||||||
SELECT ID, DEVICE_ID, STATION_CODE, CHANNEL_NUM, LATEST_REPORTING_TIME, TEMPERATURE_K, START_TEMPERATURE,
|
SELECT ID, DEVICE_ID, STATION_CODE, CHANNEL_NUM, LATEST_REPORTING_TIME, TEMPERATURE_K, START_TEMPERATURE,
|
||||||
CALIBRATION_COEFFICIENT, INITIAL_READING
|
CALIBRATION_COEFFICIENT, INITIAL_READING, DIST_FROM_OSMOSIS_METER_TO_BOTTOM
|
||||||
FROM DEVICE_INFO
|
FROM DEVICE_INFO
|
||||||
WHERE DEL = 0
|
WHERE DEL = 0
|
||||||
</select>
|
</select>
|
||||||
|
|
@ -34,7 +34,7 @@
|
||||||
RANGE, SENSOR_COEFFICIENT, MANUFACTURER, MEASURING_PROBE_NO, STEADY_WATER_LEVEL, INITIAL_WATER_LEVEL,
|
RANGE, SENSOR_COEFFICIENT, MANUFACTURER, MEASURING_PROBE_NO, STEADY_WATER_LEVEL, INITIAL_WATER_LEVEL,
|
||||||
DRILLING_SIZE, DRILLING_NO, TEMPERATURE_K, START_TEMPERATURE, PRESSURE, RECENT_DATA, CALIBRATION_COEFFICIENT,
|
DRILLING_SIZE, DRILLING_NO, TEMPERATURE_K, START_TEMPERATURE, PRESSURE, RECENT_DATA, CALIBRATION_COEFFICIENT,
|
||||||
INITIAL_READING, LATEST_REPORTING_TIME, CROSS_SECTION, DAM, MOUNTING_HEIGHT, INSTALLATION_POSITION_Z,
|
INITIAL_READING, LATEST_REPORTING_TIME, CROSS_SECTION, DAM, MOUNTING_HEIGHT, INSTALLATION_POSITION_Z,
|
||||||
INSTALLATION_POSITION_Y, INSTALLATION_POSITION_X, STATION_CODE, DEVICE_ID
|
INSTALLATION_POSITION_Y, INSTALLATION_POSITION_X, STATION_CODE, DEVICE_ID, DIST_FROM_OSMOSIS_METER_TO_BOTTOM
|
||||||
FROM DEVICE_INFO
|
FROM DEVICE_INFO
|
||||||
WHERE DEL = 0
|
WHERE DEL = 0
|
||||||
<if test="obj.deviceId != null and obj.deviceId != '' ">
|
<if test="obj.deviceId != null and obj.deviceId != '' ">
|
||||||
|
|
|
||||||
Loading…
Reference in New Issue